NS0-093 TESTDUMP | VALID NS0-093 EXAM MATERIALS

NS0-093 Testdump | Valid NS0-093 Exam Materials

NS0-093 Testdump | Valid NS0-093 Exam Materials

Blog Article

Tags: NS0-093 Testdump, Valid NS0-093 Exam Materials, Passing NS0-093 Score, NS0-093 New Dumps Book, NS0-093 Latest Exam Testking

AS the most popular NS0-093 learning braindumps in the market, our customers are all over the world. So the content of NS0-093 exam questions you see are very comprehensive, but it is by no means a simple display. In order to ensure your learning efficiency, we have made scientific arrangements for the content of the NS0-093 Actual Exam. Our system is also built by professional and specilized staff and you will have a very good user experience.

The NS0-093 certification exam is a vendor-neutral accreditation that holds international recognition in the IT industry. It’s designed for support engineers, network administrators, and technical support personnel working with NetApp storage solutions. NetApp Accredited Hardware Support Engineer certification is an ideal starting point for professionals looking to launch a career in data storage and networking, providing them with the necessary skills and knowledge to learn and grow in the field. By passing the NS0-093 Exam, you become NetApp Certified, which is a highly sought-after designation for professionals looking to advance their careers in the technology sector.

>> NS0-093 Testdump <<

100% Pass 2025 Unparalleled Network Appliance NS0-093: NetApp Accredited Hardware Support Engineer Testdump

After you really improve your strength, you will find that your strength can bring you many benefits. Users of our NS0-093 practice prep can prove this to you. You have to believe that your strength matches the opportunities you have gained. And the opportunities you get are the basic prerequisite for your promotion and salary increase. After you use our NS0-093 Exam Materials, you will more agree with this. With the help of our NS0-093 study guide, nothing is impossible to you.

Network Appliance NetApp Accredited Hardware Support Engineer Sample Questions (Q47-Q52):

NEW QUESTION # 47
During an ONTAP upgrade, nodeA1 fails to boot. You notice that it is loading the previous version of ONTAP software. What step can be taken to boot the node successfully?

  • A. From the clustershell of the partner, run system node image modify to point to the correct version of ONTAP software.
  • B. From the loader prompt of nodeA1, run boot_backup to run the correct version of ONTAP software.
  • C. From the clustershell of nodeA1, run system node image modify to point to the correct version of ONTAP software.
  • D. From the loader prompt of nodeA1, use setenv GX_PRIMARY_KERNEL_URL to point to the correct version of ONTAP software.

Answer: D

Explanation:
When a node fails to boot and loads the previous version of ONTAP, it usually indicates that the primary boot location is incorrect. To resolve this:
* Enter the LOADER Prompt:
* Interrupt the boot process to access the LOADER prompt.
* Set the Primary Kernel URL:
* Use the following command:
Steps to Boot the Correct ONTAP Version:setenv GX_PRIMARY_KERNEL_URL
<URL_to_correct_ONTAP_version>
* Boot the Node:
* Run the boot command to load the correct version.
* B. From the loader prompt of nodeA1, run boot_backup:
* Booting the backup image may result in an outdated version of ONTAP, not the desired version.
* C. From the clustershell of the partner, run system node image modify:
* Modifications to the ONTAP image must be done from the LOADER prompt, not the clustershell.
* D. From the clustershell of nodeA1, run system node image modify:
* NodeA1 cannot load ONTAP, so this command cannot be run.
Why Other Options Are Incorrect:
* "ONTAP System Boot Guide" explains how to resolve boot issues using the LOADER prompt.
* NetApp documentation on environment variables includes the use of GX_PRIMARY_KERNEL_URL.
References:


NEW QUESTION # 48
Which of the following scenarios could result in a NetApp WAFL inconsistency in a RAID DP aggregate?

  • A. two disks failing and a block error during reconstruction
  • B. two disks failing within seconds of each other
  • C. both party disks failing
  • D. rebooting a node during a disk reconstruction

Answer: A

Explanation:
A NetApp WAFL (Write Anywhere File Layout) inconsistency in a RAID-DP aggregate could occur in the following scenarios:
* Why this causes inconsistency:
* RAID-DP is designed to handle up to two concurrent disk failures. However, if a block error occurs during the reconstruction process (e.g., unreadable data on the surviving disks), the RAID group cannot rebuild the lost data, leading to WAFL inconsistencies.
1. Two disks failing and a block error during reconstruction
* Why this causes inconsistency:
* If two disks in the same RAID group fail nearly simultaneously (before the RAID-DP can reconstruct data from the first failed disk), the system cannot recover the data, resulting in WAFL inconsistencies.
2. Two disks failing within seconds of each other
* B. rebooting a node during a disk reconstruction:
* Rebooting a node does not cause WAFL inconsistency because ONTAP ensures that RAID reconstructions resume upon reboot without data loss.
* D. both party disks failing:
* This is not a valid RAID-DP term.
Why Other Options Are Incorrect:
* "WAFL and RAID-DP Operations Guide" explains failure scenarios that could cause inconsistencies.
* NetApp's "Troubleshooting RAID Groups and Aggregates" covers recovery procedures for double-disk failures and reconstruction errors.
References:


NEW QUESTION # 49
You have created a case with NetApp Support for an issue with a DS4246 shelf on an ONTAP 9.12.1 system.
They have requested that you provide shelf logs.
What action do you need to take to collect the shelf logs?

  • A. Invoke a diagnostic AutoSupport with the subsystem storage.
  • B. Invoke a diagnostic autosupport with the subsystem log_files.
  • C. Provide the output of the nodeshell command rdfile/etc/log/shelflog.
  • D. Invoke an autosupport of type all using Active IQ Unified Manager.

Answer: A

Explanation:
To collect shelf logs for a DS4246 shelf in an ONTAP 9.12.1 system, you must invoke a diagnostic AutoSupport specifically targeting the storage subsystem. This action ensures that detailed storage logs, including shelf logs, are included in the AutoSupport bundle.
* Use the following command:
Steps to Collect Shelf Logs:bash
Copy code
system node autosupport invoke -node <node_name> -type diagnostic -subsystem storage Replace <node_name> with the name of the node experiencing the issue.
* This command generates an AutoSupport message that includes logs related to storage subsystems, such as disk shelves and adapters.
* Provide the AutoSupport case number to NetApp Support for further analysis.
* A. Provide the output of the nodeshell command rdfile /etc/log/shelflog:
* While this command allows manual reading of shelf logs, it is not a recommended or comprehensive approach for collecting logs for NetApp Support cases.
* B. Invoke an AutoSupport of type all using Active IQ Unified Manager:
* This action generates a generic AutoSupport bundle, which may not include detailed shelf logs unless explicitly targeted.
* D. Invoke a diagnostic AutoSupport with the subsystem log_files:
* The log_files subsystem targets general system logs, not storage-specific logs like shelf logs.
Why Other Options Are Incorrect:
* "ONTAP 9 AutoSupport and Diagnostics Guide" outlines the use of the subsystem storage option for collecting shelf logs.
* The "Troubleshooting Storage Subsystems" documentation specifies diagnostic AutoSupport as the method for gathering shelf-related logs.
References:


NEW QUESTION # 50
You have identified that the file named quarterly_25.docx is inconsistent.
Which nodeshell command reports whether there are Snapshot copies available?

  • A. "priv set advanced; aggr wafliron start -f quarterly_25.docx"
  • B. "priv set diag; snap list -f quarterly_25.docx"
  • C. "priv set advanced; file check -f quarterly_25.docx"
  • D. "priv set diag; file check -v <voiname> -i <field>"

Answer: D


NEW QUESTION # 51
What happens when the command diskcopy is run from nodeshell?

  • A. It copies the disk content to a specified volume.
  • B. It triggers a RAID reconstruction of that disk.
  • C. It performs a low-level copy of the disk to another disk.
  • D. It pre-fails a drive in an aggregate and copies it to a spare.

Answer: C

Explanation:
Purpose of the diskcopy Command:
* The diskcopy command is used in the ONTAP nodeshell environment to perform a low-level sector-by- sector copy of data from one disk to another. This is typically used during data recovery or diagnostics.
How It Works:
* The command copies all sectors from the source disk to the destination disk without any regard for file system or metadata structures.
* It is commonly used when replicating the exact state of a failing disk to a spare for further analysis or recovery.
Key Notes:
* The destination disk must be of the same or larger capacity than the source disk.
* The operation is typically disruptive and not suitable for production use.
NetApp Reference Documentation:
* Found in the "ONTAP Command Line Manual" for nodeshell utilities. The diskcopy process is highlighted as a low-level disk cloning operation.


NEW QUESTION # 52
......

Because these NetApp Accredited Hardware Support Engineer NS0-093 exam dumps are designed by experts after in-depth research about the certification exam content. The NetApp Accredited Hardware Support Engineer exam product is made of 100% real Network Appliance NS0-093 Exam Questions verified by Network Appliance professionals. The NetApp Accredited Hardware Support Engineer NS0-093 Valid Dumps of Lead1Pass are exceptionally curated and approved by experts. We have hired professionals who after in-depth research add the most important and real test questions in three formats of our NS0-093 exam practice material.

Valid NS0-093 Exam Materials: https://www.lead1pass.com/NetworkAppliance/NS0-093-practice-exam-dumps.html

Report this page